Features
- SHEATHING AND INSULATING MATERIALS ACC. TO IEC 60092-360
- DESIGN GUIDELINES ACC. TO IEC 60092-350/353
- CHOICE AND INSTALLATION OF ELECTRIC CABLES ACC. TO IEC 60092-352
- COLD BEND TEST AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-40°C)
- COLD BEND IMPACT AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-35°C)
- ON REQUEST CLASS 5 CONDUCTOR FOR SECTIONS UP TO 10 MM²
Resistance
FIRE RESISTANT ACC. TO
IEC 60331-21
IEC 60331-2 (UNDER 20 MM Ø), IEC 60331-1 (OVER 20 MM Ø)
EN 50200 ANNEX E WATER SPRAY TEST
BS 8491 WATER JET TEST
FLAME AND FIRE RETARDANT ACC. TO
EN IEC 60332-1-2,
EN IEC 60332-3-22
HALOGEN FREE ACC. TO
EN IEC 60754-1/2
SMOKE EMISSION PROPERTIES ACC. TO
EN IEC 61034-1/2
UV RESISTANCE ACC. TO
UL 1581
OZONE RESISTANCE ACC. TO
IEC 60092-360
UL Standards
Application
FIRE RESISTANT AND WATER SPRAY RESISTANT POWER AND CONTROL CABLES FOR FIXED ELECTRICAL INSTALLATIONS ABOARD SHIPS, SUITABLE FOR THE POWER SUPPLY OF SAFETY-FIRE DEVICES. THESE CABLES PREVENT THE CABLE SHORT-CIRCUIT DUE TO WATER SPRAYS OF FIRE FIGHTERS’ HYDRANTS USED DURING THE FIRE, ALLOWING THE CONTINUOUS OPERATION OF THESE DEVICES.