Gaalship®

HF 250 ISOS FR

INDIVIDUAL & OVERALL SCREEN, INSTRUMENTATION CABLE

Construction

CONDUCTOR

PLAIN ANNEALED COPPER OR TINNED ANNEALED COPPER CONDUCTOR CL. 2, ACC. TO IEC 60228, DIN VDE 0295

INSULATION

MICA GLASS TAPE + GAALTHERM® 595

CORES COLOR

PAIR: BLACK- LIGHT BLUE TRIPLE: BLACK- LIGHT BLUE - BROWN

STRANDING

CORE LAID-UP TOGETHER IN PAIRS/TRIPLES

OVERALL SCREEN

ALUMINIUM/POLYESTER TAPE WITH TINNED ANNEALED COPPER STRANDED DRAIN WIRE

OUTER SHEATH

HALOGEN FREE THERMOPLASTIC COMPOUND SHF1
ACC. TO IEC 60092-360,
THICKNESS ACC. TO IEC 60092-376

MARKING

ELETTROTEK KABEL® GAALSHIP® HF 250 OS FR, CROSS NOMINAL SECTION mm2, 150/250 V, PART N°, IEC 60092-376, IEC 60332-3-22, IEC 60331, PRODUCTION PLANT, BATCH N°, PRODUCTION DATE, CE, ROHS, PROGRESSIVE METER MARKING.

Features

  • SHEATHING AND INSULATING MATERIALS ACC. TO: IEC 60092-360
  • DESIGN GUIDELINES ACC. TO IEC 60092-350/353
  • CHOICE AND INSTALLATION OF ELECTRIC CABLES ACC. TO IEC 60092-352
  • COLD BEND TEST AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-40°C)
  • COLD BEND IMPACT AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-35°C)
  • ON REQUEST CLASS 5 CONDUCTOR FOR SECTIONS UP TO 10 mm2

Resistance

FLAME AND FIRE RETARDANT ACC. TO

EN IEC 60332-1-2,
EN IEC 60332-3-22

HALOGEN FREE ACC. TO

EN IEC 60754-1/2

SMOKE EMISSION PROPERTIES ACC. TO

EN IEC 61034-1/2

FIRE RESISTANT ACC. TO

IEC 60331-21
IEC 60331-2 (UNDER 20 MM Ø)
IEC 60331-1 (OVER 20 MM Ø)

UV RESISTANCE ACC. TO

UL 1581

OZONE RESISTANCE ACC. TO

IEC 60092-360

Application

FIRE RESISTANT, INSTRUMENTATION CABLES FOR FIXED ELECTRICAL
INSTALLATIONS ABOARD SHIPS, SCREENED AGAINST
ELECTROMAGNETIC INTERFERENCES, COMPLYING WITH IEC 60092-352.

Technical data

NOMINAL VOLTAGE :

Uo/U 150/250 V

TEMPERATURE RANGE :

INSTALLATION TEMP.

-40°C UP TO +90°C

-20°C

SHORT CIRCUIT TEMPERATURE :

+250°C

MIN. BENDING RADIUS :

4 x OUTER DIAMETER

    Request a quotation