Gaalflex®

ROBOT 123 D

PUR torsion cable ± 450°/0,5 mt, DIN VDE 300/500 V, UL/CSA 300 V (0,14mm² – 0,34 mm²), UL/CSA 600 V (from 0,5 mm²)

Construction

CONDUCTOR

FROM 0,14 MM2 UP TO 0,34 MM2:
FLEXIBLE RED COPPER CONDUCTOR CL. 6, ACC. TO IEC 60228, DIN VDE 0295
FROM 0,50 MM2:
FLEXIBLE RED COPPER CONDUCTOR CL. 6, ACC. TO IEC 60228, DIN VDE 0295

INSULATION

TPE COMPOUND

COLOUR CORES

FROM 0,14MM2 UP TO 0,34 MM2: ACC. TO US 2
FROM 0,50 MM2: BLACK CORES WITH CONSECUTIVE NUMBERS ACC. TO EN 50334 GREEN-YELLOW FROM 3 CORES

STRANDING

IN LAYERS

WRAPPING

NETTING TAPE OVER EACH LAYER AND OVERALL NON-WOVEN TAPE

SCREEN

BARE COPPER WIRES HELICALLY WOUND

WRAPPING

NON-WOVEN TAPE

OUTER SHEATH

BLACK (RAL 9005), PUR TYPE TMPU, ACC.TO DIN VDE 0282 PART 10 + HD 22

Features

  • TUGGED AND RELIABLE
  • AWM STYLE 21060 80°C 600 V CSA AWM I/II A/B 80°C F 600 V FT1 FT2 CE
  • GOOD AGAINST ACIDS, ALKALINES, SOLVENTSHYDRAULIC LIQUIDS ETC
  • RoHS AND CE APPROVAL

Resistance

FIRE PERFORMANCE ACC. TO

UL VW1 + CSA FT1 + FT2, IEC 60332-1-2

HALOGEN FREE ACC. TO

DIN VDE 0472 part 815 + IEC 60754-1

OIL RESISTANCE

VERY GOOD-PUR TMPU ACC.TO DIN VDE 0282 PART 10 + HD 22.10

Technical data

VOLTAGE
0,14
MM2-0,34 MM2 :

UL/CSA

300 V

VOLTAGE
0,50 MM2 :

UL/CSA

MAX 600 V

PEAK OPERATING VOLTAGE
0,14 MM2-0,34 MM2 :

MAX 350 V

NOMINAL VOLTAGE
FROME 0,50 MM2 :

DIN VDE

300/500V

TEST VOLTAGE
0,14 MM2-0,34 MM2 :

1,5 KV ACC. TO DIN VDE 0472 PART. 509

TEST VOLTAGE
0,50 MM2 :

3 KV ACC. TO DIN VDE 0281 PART.2 + HD 21.2

TEMPERATURE RANGE :

FIXED LAYING

FLEXIBLE APPLICATION

UL/CSA

UP TO +80°C

UP TO +80°C

DIN VDE

-50°C UP TO +90°C

-40°C UP TO +90°C

MIN. BENDING RADIUS :

CONTINUOUSLY FLEXIBLE: 12 x D FROM 34 CORES: 20 x D

TORSION ANGLE :

UP TO ± 450°/0,5 M (TESTED)

    Request a quotation